					INPUT SPECIFICATIONS: 
				 | 
		
			| 
					Voltage …....………........…............................................... 90~264Vac 
				 | 
		
			| 
					Frequency ………………………………………………………..... 47 to 63Hz 
				 | 
		
			| 
					Inrush Current ………………….…………...................... 75A max. @240Vac 
				 | 
		
			| 
					Input Current ……….………………. 100Vac/1.6A max., 240Vac/0.8Amax. 
				 | 
		
			| 
					Leakage Current ……………………………………….…...…… 100uA max. 
				 | 
		
			| 
					OUTPUT SPECIFICATIONS: 
				 | 
		
			| 
					Holdup Time …………………………..……………….… 16ms typ. @115Vac 
				 | 
		
			| 
					Short Circuit Protection …………….....…... Hiccup Mode (Auto Recover) 
				 | 
		
			| 
					Over Voltage Protection ………………...…….... TVS Component to Clamp 
				 | 
		
			| 
					Temperature Coefficient ……………………............................... ±0.05%/℃ 
				 | 
		
			| 
					GENERAL SPECIFICATIONS: 
				 | 
					SAFETY AND EMC: 
				 | 
		
			| 
					Isolation ……………………..……………..…… Input to output = 5,656VDC 
				 | 
					Emission and Immunity ……….. EN55011 Class B, FCC CFR 47 Part 18 
				 | 
		
			| 
					Operating Temperature .......................... -20 ~ 50℃℃ (see Derating Curve) 
				 | 
					EN60601-1-2, EN61000-3-2, EN61000-3-3 
				 | 
		
			| 
					Storage Temperature …………………………....….......…........ -20~85℃℃ 
				 | 
					Safety ……………………….……… IEC60601-1, EN60601-1, UL60601-1 
				 | 
		
			| 
					Humidity ..................................................... 93% RH max. Non-Condensing 
				 | 
					NOTE: 
				 | 
		
			| 
					Cooling ………………………..…………………..……..... Natural Convection 
				 | 
					1. Voltage accuracy is set at full load. 
				 | 
		
			| 
					Switching Frequency …………………………………….……. 65KHz Typical 
				 | 
					2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for 
				 | 
		
			| 
					MTBF ……………….… MIL-HDBK-217F, GB, 25℃/115VAC …… T.B.D hrs 
				 | 
					Ripple & Noise measuring @20MHz BW. 
				 | 
		
			| 
					Altitude ……………………..……………………….…………………… 3000m 
				 | 
					3. Line regulation is measured from 100Vac to 240Vac with full load. 
				 | 
		
			| 
					Dimensions ……….….. 4.000x2.000x1.100inches (101.6x50.8x27.94mm) 
				 | 
					4. Load regulation is measured from 10% to 100% full load. 
				 |